Have a personal or library account? Click to login
Hepa Filter Material Load Detection Using a Microwave Cavity Sensor Cover

Hepa Filter Material Load Detection Using a Microwave Cavity Sensor

Open Access
|Dec 2017

Abstract

This paper presents a novel microwave cavity sensor application for the detection of HEPA filter particulate loading. The sensor resonates at 3.435GHz and 8.570GHz when empty, where the TM010 and TM020 modes dominate respectively. Experimental results show that the resonant frequency of the sensor shifts significantly when filters of different particulate loadings are presented to it. This is a significant finding, and means that the sensor could present an effective solution for determining the loading of periodic use HEPA filters (e.g. those used in personal respirators), which are often disposed of unnecessarily.

Language: English
Page range: 322 - 337
Published on: Dec 13, 2017
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2017 A. Mason, S. Wylie, A. Thomas, H. Keele, A. Shaw, A.I. Al-Shamma’a, published by Professor Subhas Chandra Mukhopadhyay