Calibration of Structured Light Scanning System Cover
By: Yi Guo and  Xiaoyi Ruan  
Open Access
|Feb 2022

Figures & Tables

Figure 1.

The measurement system

Figure 2.

Schematic diagram of camera imaging

Figure 3.

Principle of camera imaging

Figure 4.

Camera distortion

Figure 5.

Rasterization of the checkerboard calibration board

Figure 6.

Design drawing of calibration board

Figure 7.

The calibration process based on circular marking points

Figure 8.

Main view of calibration board

Figure 9.

Position relationship diagram between points and straight lines

Figure 10.

Automatic matching of marking points at different angles

THE BACK PROJECTION ERROR RESULTS OF THE ALGORITHM

Group ea em
10.1910.650
20.1770.801
30.2660.502

MEASUREMENT INFORMATION OF DENTAL MODEL (UNIT: MM)

NameAverage measurement result of this systemMeasurement standard deviationLJ-V7000measurement results
Arch length63.870.1063.91
Arch width58.020.1258.03
41 teeth5.580.125.63
42 teeth6.520.096.45
43 teeth7.280.117.32
44 teeth7.890.177.89
45 teeth7.480.067.46
46 teeth11.000.0710.97
31 teeth5.410.085.41
32 teeth6.390.106.31
33 teeth6.980.077.06
34 teeth7.790.127.76
35 teeth7.450.077.43
36 teeth11.050.1310.95

BACK-PROJECTION ERROR RESULTS OF ZHANG'S CALIBRATION METHOD

Group ea e m
10.6131.124
20.6912.316
30.8271.528
Language: English
Page range: 56 - 64
Published on: Feb 21, 2022
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2022 Yi Guo, Xiaoyi Ruan, published by Xi’an Technological University
This work is licensed under the Creative Commons Attribution 4.0 License.