Have a personal or library account? Click to login

Contribution To The Short Measurement Method For Determining The Thermal Characteristics Of Existing Buildings: Total Heat Transmission Coefficient Estimation Based On Double Measurement

Open Access
|Aug 2018

References

  1. Kośny J., Kossecka E.; Multi-dimensional heat transfer through complex building envelope assemblies in hourly energy simulation programs, Energy and Buildings 34 (2002), p.445-454
  2. Byrne A., Byrne G., Davies A., Robinson A. J.; Transient and quasi-steady thermal behaviour of a building envelope due to retrofitted cavity wall and ceiling insulation, Energy and Buildings 61 (2013), p.356-365
  3. Laurenti L., Marcotullio F., De Monte F.; Determination of the thermal resistance of walls through a dynamic analysis of in-situ data, International Journal of Thermal Sciences 43 (2004), p.297-306
  4. Oral G. K., Yilmaz Z.; The limit U values for building envelope related to building form in temperate and cold climatic zones, Building and Environment 37 (2002), p.1173-1180
  5. Al-Sanea S. A., Zedan M. F., Al-Hussain S. N.; Effect of thermal mass on performance of insulated building walls and the concept of energy savings potential, Applied Energy 89 (2012), p.430-442
  6. Bellamy L.; Towards the development of new energy performance indicators for the external walls of residential buildings, Energy and Buildings, 68 (2014), p.696-702
  7. Albatici R.; On site evaluation of U-value of opaque building elements: a new methodology, Passive and Low Energy Architecture (PLEA) Conference, Dublin, Ireland 2008
  8. Lee S., Kato S.; Feasibility study of in situ measurement method using the infrared camera to measure u-value of walls on residential house installed an convection stove, Journal of Environmental Engineering 76 (2011), p.289-295
  9. Roels S.; Reliable building energy performance characterization based on full scale dynamic measurements, International Energy Agency EXCO Energy Conservation in Buildings and Community Systems Annex 58, 2011
  10. Bacher P., Madsen H.; Identifying suitable models for the heat dynamics of buildings, Energy and Buildings 43 (2011), p.1511-1522
  11. Santamouris M.et al.; Energy performance of residential buildings: a practical guide for energy rating and efficiency. James&James/Earthscan. p.140, 2005
  12. Abadie M., Mendes N.; Comparative Analysis of Response-factor and Finite-volume based Methods for predicting Heat and Moisture Transfer through Porous Building Materials, Journal of Building Physics 30 (2006), p.7-37
  13. Sjögren J-U., Andersson S., Olofsson T., Sensitivity of the total heat loss coefficient determined by the energy signature approach to different time periods and gained energy, Energy and Buildings 41 (2009), p.801-808
  14. Oschatz B.; Physikalische Bewertung vorgeschlagener Messverfahren zur energetischen Inspektion von Heizungsanlagen. Des Bundesministerium für Verkehr, Bau und Stadtentwicklung. Dresden, 2006
  15. Donath M.; Analyse des Betriebsverhaltens von Heizungsanlagen bei der Wärmeversorgung von Gebäuden. Dissertation. Universität Rostock, 2012
  16. Foit H., Szewczyk M.; Określanie zapotrzebowania na ciepło końcowe budynku mieszkalnego na podstawie krótkotrwałego pomiaru (Determination of heat demand of residential building based on brief measurement), Rynek Energii 97 (2011), p.86-91 (in Polish)
  17. Foit H. et al.; Poradnik Diagnostyki cieplnej budynków Tom 2 (Handbook of Thermal Diagnostics of Buildings Vol.2). Wydawca Politechnika Śląska. p.346, 2013 (in Polish)
  18. Foit H., Świerc A.; Wyznaczanie wymaganej mocy źródła ciepła na potrzeby diagnostyki cieplnej budynku mieszkalnego. (Measurement based determination of demanded power of heat source for thermal diagniostics of dwelling houses), Rynek Energii 102 (2012), p.76-80 (in Polish)
  19. Świerc A., Foit H.; Evaluation of required heat source power in existing buildings based on short measurements. Pastatu inzinerines sistemos. 16-osios jaunuju mokslininku konferencijos “Mokslas – Lietuvos ateitis” (Engineering systems for Buildings. Proceedings of the 16th Conference for Junior Researchers “Science – Future of Lithuania”). Vilniaus Gedimino Technikos Universitetas. Aplinkos inzinerijos fakultetas. Vilnius: Technika, p.140-145, 2013
  20. Foit H., Świerc A., Szewczyk M.; Miarodajna temperatura zewnętrzna na potrzeby charakterystyki energetycznej budynku (Equivalent external temperature for energy performance of buildings), Rynek Energii 106 (2013), p.108-112 (in Polish)
  21. EN 15378:2007 Heating systems in buildings – Inspection of boilers and heating systems.
  22. Świerc A., Świerc S., Foit H., Koper P., Applying the Exodus method to calculate the set of impulse response functions of a wall, Energy and Buildings 69 (2014), p.301-306
  23. Directive 2010/31/EU of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings (recast)
  24. Directive 2002/91/EC of the European Parliament of the Council of 16 December 2002 on the energy performance of buildings
  25. Rozporządzenie Ministra Infrastruktury dnia 6 listopada 2008r. w sprawie metodologii obliczania charakterystyki energetycznej budynku i lokalu mieszkalnego lub części budynku stanowiącej samodzielną całość techniczno-użytkową oraz sposobu sporządzania i wzorów świadectw ich charakterystyki energetycznej, Dz. U. Nr 201, poz.1240 (Regulation of the Polish Minister of Infrastructure. Methodology for calculating the energy performance of buildings)
  26. EN 12831:2003 Heating systems in buildings – Method for calculation of the design heat load
DOI: https://doi.org/10.21307/acee-2017-011 | Journal eISSN: 2720-6947 | Journal ISSN: 1899-0142
Language: English
Page range: 103 - 116
Submitted on: Jan 23, 2016
Accepted on: Dec 5, 2016
Published on: Aug 27, 2018
Published by: Silesian University of Technology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 times per year

© 2018 Henryk Foit, Agata ŚWierc, Wojciech Foit, published by Silesian University of Technology
This work is licensed under the Creative Commons Attribution 4.0 License.