Have a personal or library account? Click to login
Numerical and experimental determination of in-structure temperature profiles Cover

Numerical and experimental determination of in-structure temperature profiles

Open Access
|Jul 2015

References

  1. [1] Li, Q., Rao, J. & Fazio, P. (2009). Development of HAM tool for building envelope analysis. Building and Environment. Volume 44. 1065-1673.10.1016/j.buildenv.2008.07.017
  2. [2] Huang, H., Kato, S., Hu, R. & Ishida, Y. (2011). Development of new indices to assess the contribution of moisture sources to indoor humidity and application to optimization design: Proposal of CRI (H) and a transient simulation for the prediction of indoor humidity. Building and Environment. Volume 46. 1817-1826.10.1016/j.buildenv.2011.03.002
  3. [3] Woloszyn, M. & Rode, C. (2009). Tools for Performance Simulation of Heat, Air and Moisture Conditions of Whole Buildings. Building Simulation. Volume 1. 5-24.10.1007/s12273-008-8106-z
  4. [4] Katunský, D., Vertaľ, M., Šimiček, J. & Zozulák, M. 2014. Numerical analysis and measurement results of a window sill. Advanced Materials Research. Volume 899, 147-15010.4028/www.scientific.net/AMR.899.147
  5. [5] Janssens, A., Roels, S. & Vandaele, L. (2011). Full scale test facilities for evaluation of energy and hygrothermal performances. Paper presented at International Workshop. Brussels, Belgium.
  6. [6] Baker, P.H. & van Dijk, H.A.L. (2008). PASLINK and dynamic outdoor testing of building components. Building and Environment. Volume 43, 143-151.10.1016/j.buildenv.2006.10.009
  7. [7] Strachan, P.A. & Vandaele, L. (2008). Case studies of outdoor testing and analysis of building components. Building and Environment. Volume 43, 129-142.10.1016/j.buildenv.2006.10.043
  8. [8] Fraunhofer Institute for Building Physics WUFI (2011, Jun). Creating Weather Files. Retrieved Jun 16, 2011, from http://www.wufi.de/frame_en_wetterdaten.html
  9. [9] Physibel. (2013). User manual for Physibel [computer software]. Maldegem, Belgium: Physibel.
  10. [10] Katunský, D., Vertaľ, M. & Zozulák, M. (2014). Experimentally Measured Boundary and Initial Conditions for Simulations. Advanced Materials Research. Volume 1041, 293-296.10.4028/www.scientific.net/AMR.1041.293
  11. [11] Vertaľ, M., Katunský, D. & Buriková, D. (2012). Water profile as initial condition for HAM analysis. Thermal Protection of Buildings. Volume 5, 3-6. (In Slovak).
DOI: https://doi.org/10.1515/sspjce-2015-0007 | Journal eISSN: 1338-7278 | Journal ISSN: 1336-9024
Language: English
Page range: 65 - 72
Published on: Jul 1, 2015
In partnership with: Paradigm Publishing Services
Publication frequency: 2 issues per year

© 2015 Marek Zozulák, Dušan Katunský, published by Technical University of Košice
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.