Abstract

Background. The aim of the study was to investigate whether biologically effective dose (BED) based on linearquadratic model can be used to estimate spinal cord tolerance dose in spine stereotactic body radiation therapy (SBRT) delivered in 4 or more fractions.

Patients and methods. Sixty-three metastatic spinal lesions in 47 patients were retrospectively evaluated. The most frequently prescribed dose was 36 Gy in 4 fractions. In planning, we tried to limit the maximum dose to the spinal cord or cauda equina less than 50% of prescription or 45 Gy2/2. BED was calculated using maximum point dose of spinal cord.

Results. Maximum spinal cord dose per fraction ranged from 2.6 to 6.0 Gy (median 4.3 Gy). Except 4 patients with 52.7, 56.4, 62.4, and 67.9 Gy2/2, equivalent total dose in 2-Gy fraction of the patients was not more than 50 Gy2/2 (12.1- 67.9, median 32.0). The ratio of maximum spinal cord dose to prescription dose increased up to 82.2% of prescription dose as epidural spinal cord compression grade increased. No patient developed grade 2 or higher radiationinduced spinal cord toxicity during follow-up period of 0.5 to 53.9 months.

Conclusions. In fractionated spine SBRT, BED can be used to estimate spinal cord tolerance dose, provided that the dose per fraction to the spinal cord is moderate, e.g. < 6.0 Gy. It appears that a maximum dose of up to 45-50 Gy2/2 to the spinal cord is tolerable in 4 or more fractionation regimen.

DOI: https://doi.org/10.1515/raon-2015-0008 | Journal eISSN: 1581-3207 | Journal ISSN: 1318-2099
Language: English
Page range: 185 - 191
Submitted on: Nov 7, 2014
|
Accepted on: Jan 5, 2015
|
Published on: Mar 25, 2015
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2015 Seung Heon Lee, Kyu Chan Lee, Jinho Choi, So Hyun Ahn, Seok Ho Lee, Ki Hoon Sung, Se Hee Kil, published by Association of Radiology and Oncology
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.