Have a personal or library account? Click to login
Study of Harmonic Detection Methods under Non-Ideal Conditions in Ship Power Network Cover

Study of Harmonic Detection Methods under Non-Ideal Conditions in Ship Power Network

Open Access
|Oct 2015

Abstract

An improved harmonic detection method based on average arithmetic is proposed. According to the research results, the designed solution uses an LPF (low-pass-filter) and a mean value module connected in series instead of the conventional mean value module, and simultaneously, a three-phase voltage phase-locked module instead of commonly used PLL (phase lock loop) module is applied in order to reduce the influence caused by three-phase distorted voltage and rapid variation of load. The experimental results show that the application of this solution leads to increase in the accuracy of harmonics detection for distorted three-phase voltage and rapid variation of load.

DOI: https://doi.org/10.1515/pomr-2015-0060 | Journal eISSN: 2083-7429 | Journal ISSN: 1233-2585
Language: English
Page range: 82 - 89
Published on: Oct 15, 2015
Published by: Gdansk University of Technology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2015 Xiao-Yan Xu, Janusz Mindykowski, Tomasz Tarasiuk, Chen Cheng, published by Gdansk University of Technology