Have a personal or library account? Click to login
Photon beam commissioning of an Elekta Synergy linear accelerator Cover

Photon beam commissioning of an Elekta Synergy linear accelerator

Open Access
|Dec 2017

References

  1. [1] Narayanasamy G, Saenz D, Cruz W, et al. Commissioning an Elekta Versa HD linear accelerator. J Appl Clin Med Phys. 2016;17(1):179-191.10.1120/jacmp.v17i1.5799569021726894351
  2. [2] Allen J. White Paper: High Dose Rate mode (Flattening Filter Free) Radiotherapy Clinical advantages of High Dose Rate mode, available with Agility™ on Elekta’s Versa HD™ linear accelerator [white paper]. 2014.
  3. [3] Boda-Heggemann J, Mai S, Fleckenstein J, et al. Flattening-filter-free intensity modulated breath-hold image-guided SABR (Stereotactic ABlative Radiotherapy) can be applied in a 15-min treatment slot. Radiother Oncol. 2013;109(3):505-509.10.1016/j.radonc.2013.09.01424128805
  4. [4] Das IJ, Cheng CW, Watts RJ, et al. Accelerator beam data commissioning equipment and procedures: report of the TG-106 of the Therapy Physics Committee of the AAPM. Med Phys. 2008;35(9):4186-4215.10.1118/1.296907018841871
  5. [5] Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: quality assurance of medical accelerators. Med Phys. 2009;36(9):4197-4212.10.1118/1.319039219810494
  6. [6] Almond PR, Biggs PJ, Coursey BM, et al. AAPM’s TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999;26(9):1847-1870.10.1118/1.59869110505874
  7. [7] Niroomand-Rad A, Blackwell CR, Coursey BM, et al. Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. Med Phys. 1998;25(11):2093-2115.10.1118/1.5984079829234
  8. [8] International Electrotechnical Commission. Medical electrical equipment. Part 2: Particular requirements for the safety of gamma beam therapy equipment. IEC 60601-2-11. Geneva, Switzerland: IEC; 1987.
  9. [9] Pönisch F, Titt U, Vassiliev ON, et al. Properties of unflattened photon beams shaped by a multileaf collimator. Med Phys. 2006;33(6):1738-1746.10.1118/1.220114916872081
  10. [10] Stathakis S, Esquivel C, Gutierrez A, et al. Treatment planning and delivery of IMRT using 6 and 18 MV photon beams without flattening filter. Appl Radiat Isot. 2009;67(9):1629-1637.10.1016/j.apradiso.2009.03.01419369083
  11. [11] Weber L, Nilsson P, Ahnesjö A. Build-up cap materials for measurement of photon head-scatter factors. Phys Med Biol. 1997;42(10):1875-1886.10.1088/0031-9155/42/10/0029364584
  12. [12] Jursinic PA. Measurement of head scatter factors of linear accelerators with columnar miniphantoms. Med Phys. 2006;33(6):1720-1728.10.1118/1.220114816872079
  13. [13] Dieterich S, Sherouse GW. Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors. Med Phys. 2011;38(7):4166-4173.10.1118/1.359264721859018
  14. [14] Phillips MH, Parsaei H, Cho PS. Dynamic and omni wedge implementation on an Elekta SL linac. Med Phys. 2000;27(7):1623-1634.10.1118/1.59902910947266
  15. [15] Thompson CM, Weston SJ, Cosgrove VC, Thwaites DI. A dosimetric characterization of a novel linear accelerator collimator. Med Phys. 2014;41(3):031713.10.1118/1.486622824593717
  16. [16] International Electrotechnical Commission. Medical electrical equipment — Part 2.1. Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV. IEC 60601–2-1 Ed. 3.0. Geneva, Switzerland: IEC; 2009.
  17. [17] Chang Z, Wu Q, Adamson J, et al. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines. Med Phys. 2012;39(11):6981-7018.10.1118/1.476268223127092
  18. [18] Kragl G, af Wetterstedt S, Knäusl B, et al. Dosimetric characteristics of 6 and 10 MV unflattened photon beams. Radiother Oncol. 2009;93(1):141-146.10.1016/j.radonc.2009.06.00819592123
  19. [19] Benedict SH, Yenice KM, Followill D, et al. Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys. 2010;37(8):4078-4101.10.1118/1.343808120879569
  20. [20] Glide-Hurst C, Bellon M, Foster R, et al. Commissioning of the Varian TrueBeam linear accelerator: a multi-institutional study. Med Phys. 2013;40(3):031719.10.1118/1.479056323464314
  21. [21] Cashmore J. The characterization of unflattened photon beams from a 6 MV linear accelerator. Phys Med Biol. 2008;53(7):1933-1346.10.1088/0031-9155/53/7/00918364548
  22. [22] Vassiliev ON, Titt U, Pönisch F, et al. Dosimetric properties of photon beams from a flattening filter free clinical accelerator. Phys Med Biol. 2006;51(7):1907-1917.10.1088/0031-9155/51/7/01916552113
DOI: https://doi.org/10.1515/pjmpe-2017-0019 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 115 - 119
Submitted on: Jan 16, 2017
Accepted on: Sep 19, 2017
Published on: Dec 21, 2017
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2017 Md Abdullah Al Mashud, M Tariquzzaman, M Jahangir Alam, GA Zakaria, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.