Effective energy measurement using radiochromic film: application of a mobile scanner Cover

References

  1. [1] Shepard SJ, Lin PP, Boone JM, et al. Quality control in diagnostic radiology. Madison, WI: Medical Physics Publishing, AAPM Report No 74; 2002.
  2. [2] Butson MJ, Yu PKN, Cheung T, et al. Radiochromic film for medical radiation dosimetry. Mat Sci EngR, 2003;41(3): 61-120.10.1016/S0927-796X(03)00034-2
  3. [3] Cheung T, Butson MJ, Yu PK. Reflection spectrometry analysis of irradiated GAFCHROMIC XR type R radiochromic films. Appl Radiat Isot, 2005;63(1):127-129.10.1016/j.apradiso.2005.02.00315866457
  4. [4] Gotanda T, Katsuda T, Gotanda R, et al. Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density. Australas Phys Eng Sci Med. 2009;32(1),26-29.
  5. [5] Gotanda T, Katsuda T, Gotanda R, et al. Half-value layer measurement: simple process method using radiochromic film. Australas Phys Eng Sci Med. 2009;32(3):150-158.10.1007/BF0317864219873939
  6. [6] Gotanda T, Katsuda T, Gotanda R, et al. Evaluation of effective energy using radiochromic film and a step-shaped aluminum filter. Australas Phys Eng Sci Med. 2011;34(2):213-222.10.1007/s13246-011-0068-221437731
  7. [7] International Specialty Products [Internet]. [cited 2016 October 18]. Available from: http://www.veritastk.co.jp/attached/2062/GAFCHROMICEBT2TechnicalBrief-Rev1.pdf
  8. [8] Sutherland JG, Rogers DW. Monte Carlo calculated absorbed-dose energy dependence of EBT and EBT2 film. Med Phys. 2010;37(3):1110-1116.10.1118/1.3301574283772620384246
  9. [9] Dini SA, Koona RA, Ashburn JR, et al. Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films. J Appl Clin Med Phys. 2005;6(1):114-134.10.1120/jacmp.v6i1.2051572350315770202
  10. [10] Butson MJ, Cheung T, Yu PK. XR type-R radiochromic film x-ray energy response. Phys Med Biol. 2005;50(15):N195-N199.10.1088/0031-9155/50/15/N0416030377
  11. [11] Fletcher CL, Mills JA. An assessment of GafChromic film for measuring 50 kV and 100 kV percentage depth dose curves. Phys Med Biol. 2008;53(11):N209-N218.10.1088/0031-9155/53/11/N0218490809
  12. [12] Butson MJ, Cheung T, Yu PK. Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range. Appl Radiat Isot. 2006;64(1):60-62.10.1016/j.apradiso.2005.07.00216105740
  13. [13] Tomic N, Devic S, DeBlois F, et al. Reference radiochromic film dosimetry in kilovoltage photon beams during CBCT image acquisition. Med Phys. 2010;37(3):1083-1092.10.1118/1.330214020384244
  14. [14] Butson MJ, Yu PK, Cheung T, et al. Energy response of the new EBT2 radiochromic film to x-ray radiation. Radiat Meas. 2010;45(7):836-839.10.1016/j.radmeas.2010.02.016
  15. [15] Rink A, VitkinIA, Jaffray DA. Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter. Med Phys. 2007;34(2):458-463.10.1118/1.243142517388161
  16. [16] Gotanda T, Katsuda T, Akagawa T, et al. Evaluation of GAFCHROMIC EBT2 dosimetry for the low dose range using a flat-bed scanner with the reflection mode. Australas Phys Eng Sci Med. 2013;36(1):59-63.10.1007/s13246-013-0187-z23479183
  17. [17] Butson E, Alnawaf H, Yu PK, et al. Scanner uniformity improvements for radiochromic film analysis with matt reflectance backing. Australas Phys Eng Sci Med. 2011;34(3):401-407.10.1007/s13246-011-0086-021735295
  18. [18] Cheung T, Butson MJ, Yu PK. Post-irradiation colouration of Gafchromic EBT radiochromic film. Phys Med Biol. 2005;50(20):N281-N285.10.1088/0031-9155/50/20/N0416204869
  19. [19] EPSON [Internet]. [cited 2009 August 15]. Available from: http://www.epson.jp/support/manual/scanner/es2200.htm/
  20. [20] exemode [Internet]. [cited 2010 November 15]. Available from: http://www.exemode.com/yashica/fs/s40.html/
  21. [21] Seltzer SM, Hubbell JH. Tables and Graphs of Photon Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients for Photon Energies 1 keV to 20 MeV for Elements Z = 1 to 92 and Some Dosimetric Materials. National Institute of Standards and Technology; 1995. 10.6028/NIST.IR.5632
DOI: https://doi.org/10.1515/pjmpe-2016-0015 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 85 - 92
Submitted on: Jul 19, 2016
Accepted on: Nov 3, 2016
Published on: Dec 30, 2016
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2016 Tatsuhiro Gotanda, Toshizo Katsuda, Rumi Gotanda, Tadao Kuwano, Takuya Akagawa, Nobuyoshi Tanki, Akihiko Tabuchi, Tetsunori Shimono, Yasuyuki Kawaji, Yoshihiro Takeda, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.