Have a personal or library account? Click to login
Stereotactic radiosurgery of prostate cancer – dose distribution for VMAT and CyberKnife techniques Cover

Stereotactic radiosurgery of prostate cancer – dose distribution for VMAT and CyberKnife techniques

Open Access
|Jul 2016

References

  1. [1] Chin LS, Regine WF, editors. Principles and Practice of Stereotactic Radiosurgery. Springer; 2008.10.1007/978-0-387-71070-9
  2. [2] Hernández TG, Gonzáleza AV, Peidro JP, et al. Radiobiological comparison of two radiotherapy treatment techniques for high-risk prostate cancer. Rep Pract Oncol Radiother. 2013;18(5):265-271.10.1016/j.rpor.2012.12.006
  3. [3] Ślosarek K, Rembielak A, Maciejewski B. Dynamiczna radiochirurgia - nowe możliwości radioterapii stereotaktycznej. Nowotwory J Oncol. 2003;53(5):546-551.
  4. [4] Stąpór-Fudzińska M, Grządziel A, Ślosarek K. Influence of the beam number reduction on the treatment plan quality in the cyberknife system. Onkologia info. 2011;T8, 2(39):120.
  5. [5] Wigg DR. Applied Radiobiology and Bioeffect Planning. Madison, Wisconsin: Medical Physics Publishing; 2001.10.1120/1.1435082
  6. [6] de Crevoisier R, Castelli J, Guérif S, et al. Cancers deprostate: quelles techniques de radiothérapie pour quelles tumeurs ? Enjeuxé thiques et méthodologiques. Cancer/Radiothérapie. 2014;18(5-6):369-378.10.1016/j.canrad.2014.07.154
  7. [7] Cranmer-Sargison G, Kundapur V, Tu D, et al. Using kV-kV and CBCT imaging to evaluate rectal cancer patient position when treated prone on a newly available belly board. Med Dosim. 2012;37(2):117-121.10.1016/j.meddos.2011.02.002
  8. [8] Feuvret L, Noël G, Mazeron JJ, Bey P. Conformity Index: a review. Int J Radiat Onc Biol Phys. 2006;64(2):333-342.10.1016/j.ijrobp.2005.09.028
  9. [9] Ślosarek K, Grządziel A, Szlag M, Bystrzycka J. Radiation Planning Index for dose distribution evaluation in stereotactic radiotherapy. Rep Pract Oncol Radiother. 2008;13(4):182-186.10.1016/S1507-1367(10)60007-7
  10. [10] Projekt medyczny: Radioterapia konformalna , konwencjonalnie frakcjonowana (CF-CRT) w połączeniu z hypofrakcjonowanym boostem stereotaktycznym u chorych na raka prostaty o średnim i wysokim ryzyku nawrotu - badanie pilotowe, Centrum Onkologii - Instytut MSC Gliwice, 2012.
  11. [11] Protokół radykalnej frakcjonowanej radioterapii stereotaktycznej, CyberKnife chorych na raka gruczołu krokowego, Centrum Onkologii - Instytut MSC Gliwice, 2012.
  12. [12] Eclipse™ Treatment Planning System [Internet]. [cited 2016 May 18]. Available from: http://www.varian.com/oncology/products/software/treatment-planning/eclipse
  13. [13] CyberKnife Treatment Planning System [Internet]. [cited 2016 May 18]. Available from: http://www.accuray.com/solutions/treatment-planning/cyberknife-treatment-planning-system
  14. [14] Osewski W. Rekonstrukcja rozkładu dawki w technikach dynamicznych: IMRT i VMAT [PhD dissertation]. Katowice: Uniwersytet Śląski; 2013.
  15. [15] Osewski W, Dolla Ł, Radwan M, et al. Clinical examples of 3D dose distribution reconstruction, based on the actual MLC leaves movement, for dynamic treatment techniques. Rep Pract Oncol Radiother. 2014;19(6):420-427.10.1016/j.rpor.2014.04.013420177125337416
  16. [16] Lin YW, Lin KH, Ho HW, et al. Treatment plan comparison between stereotactic body radiation therapy techniques for prostate cancer: non-isocentric CyberKnife versus isocentric RapidArc. Physica Medica. 2014;30(6):654-661.10.1016/j.ejmp.2014.03.00824726212
  17. [17] MacDougall ND, Dean C, Muirhead R. Stereotactic Body Radiotherapy in Prostate Cancer: Is Rapidarc a Better Solution than Cyberknife? Clin Oncol. 2014;26(1):4-9.10.1016/j.clon.2013.08.00824071450
  18. [18] Leszczyński W, Ślosarek K, Szlag M. Comparison of dose distribution in MRT and RapidArc technique in prostate radiotherapy. Rep Pract Oncol Radiother. 2012;17(6):347-351.10.1016/j.rpor.2012.05.002386325324377036
  19. [19] Ceylan C, Kucuk N, Ayata HB. Dosimetric and physical comparison of IMRT and CyberKnife plans in the treatment of localized prostate cancer. Rep Pract Oncol Radiother. 2010;15(6)181-189.10.1016/j.rpor.2010.10.003386315424376947
  20. [20] Henderson DR, Tree AC, van As NJ. Stereotactic Body Radiotherapy for Prostate Cancer. Clin Oncol. 2015;27(5): 270-279.10.1016/j.clon.2015.01.01125707911
  21. [21] Zaorsky NG, Studenski MT, Dicker AP, et al. Stereotactic body radiation therapy for prostate cancer: Is the technology ready to be the standard of care? Cancer Treat Rev. 2013;39(22):212-218.10.1016/j.ctrv.2012.10.00323218442
  22. [22] Fenwick JD, Tomé WA, Soisson ET, et al. Tomotherapy and Other Innovative IMRT Delivery Systems. Semin Radiat Oncol. 2006;16(4):199-208.10.1016/j.semradonc.2006.04.00217010902
  23. [23] Ślosarek K, Osewski W, Grządziel A, et al. Integral dose: Comparison between four techniques for prostate radiotherapy. Rep Pract Oncol Radiother. 2015;20(2):99-103.10.1016/j.rpor.2014.10.010433821625859398
  24. [24] Osewski W, Ślosarek K, Karaszewska B. Dose distribution transfer from CyberKnife to Varian treatment planning system. J Phys: Conf Ser. 2014;489(1):12056. 10.1088/1742-6596/489/1/012056
DOI: https://doi.org/10.1515/pjmpe-2016-0007 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 35 - 40
Published on: Jul 2, 2016
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2016 Krzysztof Ślosarek, Wojciech Osewski, Aleksandra Grządziel, Małgorzata Stąpór-Fudzińska, Marta Szlag, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.