Optimization of soft X-ray tomography on the COMPASS tokamak Cover

Optimization of soft X-ray tomography on the COMPASS tokamak

Open Access
|Oct 2016

References

  1. 1. Panek, R., Bilková, P., Fuchs, V., Hron, M., Chraska, P., Stockel, J., Urban, J., Weinzettl, V., Zajac, J., & Zacek, F. (2006). Reinstallation of the COMPASS-D tokamak in IPP ASCR. Czech. J. Phys., 56(Suppl. 2), B125-B137. DOI: 10.1007/s10582-006-0188-1.10.1007/s10582-006-0188-1
  2. 2. Weinzettl, V., Naydenkova, D. I., Sestak, D., Vlcek, J., Mlynar, J., Melich, R., Jares, D., Malot, J., Sarychev, D., & Igochine, V. (2010). Design of multi-range tomographic system for transport studies in tokamak plasmas. Nucl. Instrum. Methods Phys. Res. Sect. AAccel. Spectrom. Dect. Assoc. Equip., 623, 806-808. DOI: 10.1016/j.nima.2010.04.010.10.1016/j.nima.2010.04.010
  3. 3. Anton, M., Weisen, H., Dutch, M. J., Linden, W., Buhlmann, F., Chavan, R., Marletaz, B., Marmillod, P., & Paris, P. (1996). X-ray tomography on the TCV tokamak. Plasma Phys. Control. Fusion, 38, 1849-1878. DOI: 10.1088/0741-3335/38/11/001.10.1088/0741-3335/38/11/001
  4. 4. Odstrcil, M., Mlynar, J., Odstrcil, T., Alper, B., Murari, A., & JET EFDA Contributors. (2012). Modern numerical methods for plasma tomography optimization. Nucl. Instrum. Methods Phys. Res. Sect. A-Accel. Spectrom. Dect. Assoc. Equip., 686, 156-161.10.1016/j.nima.2012.05.063
  5. 5. Mazon, D., Vezinet, D., Pacella, D., Moreau, D., Gabelieri, L., Romano, A., Malard, P., Mlynar, J., Masset, R., & Lotte, P. (2012). Soft x-ray tomography for real-time applications: present status at Tore Supra and possible future developments. Rev. Sci. Instrum., 83(6), 063505. DOI: 10.1063/1.4730044.10.1063/1.4730044
  6. 6. Loffelmann, V., Mlynar, J., Imrisek, M., Mazon, D., Jardin, A., Weinzettl, V., & Hron, M. (2016). Minimum Fisher Tikhonov regularization adapted to real-time tomography. Fusion Sci. Technol., 69(2), 505-513.10.13182/FST15-180
  7. 7. Ingesson, L. C., Alper, B., Peterson, B. J., & Vallet, J. -C. (2008). Tomography diagnostics: Bolometry and soft X-ray detection. Fusion Sci. Technol., 53(2), 528-576.10.13182/FST53-528
DOI: https://doi.org/10.1515/nuka-2016-0066 | Journal eISSN: 1508-5791 | Journal ISSN: 0029-5922
Language: English
Page range: 403 - 408
Submitted on: Sep 3, 2015
Accepted on: Nov 11, 2015
Published on: Oct 26, 2016
Published by: Institute of Nuclear Chemistry and Technology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 times per year

© 2016 Martin Imríšek, Jan Mlynář, Viktor Löffelmann, Vladimír Weinzettl, Tomáš Odstrčil, Michal Odstrčil, Matěj Tomeš, published by Institute of Nuclear Chemistry and Technology