An Inter-Laboratory Comparison for the Urinary Acrolein Biomarker 3-Hydroxypropyl-Mercapturic Acid (3-HPMA)

Open Access
|Feb 2017

Abstract

An inter-laboratory comparison study on the acrolein biomarker of exposure 3-hydroxypropyl-mercapturic acid (3-HPMA) with 12 laboratories from 7 globally distributed countries was performed. The laboratories received coded triplicates of 4 spiked and lyophilized urine samples (LU, 12 samples) as well as 5 authentic urine pool samples (PU, 15 samples) covering the 3-HPMA concentration range from background (non-smoking) to heavy smoking levels for analysis by using their own (in-house) analytical method. All laboratories applied liquid chromatography with tandem mass spectrometry (LC-MS/MS), with most of them (10 of 12) using solid phase extraction (SPE) as sample work-up procedure. The intra-laboratory variation (indicating repeatability) was determined by calculating the standard deviation (sr) and the coefficient of variation (CVr) of the triplicates, whereas the inter-laboratory variation (indicating reproducibility) was determined by calculating the standard deviation between laboratories (sR) and the corresponding coefficient of variation (CVR). After removal of outlier samples or laboratories, the mean CVr values for LU and PU test samples ranged from 2.1–3.6% (mean: 2.8%) and 2.4–3.7% (mean: 3.3%), respectively, indicating good repeatability for the determination of 3-HPMA in both sample types. CVR for LU and PU test samples ranged from 9.1–31.9% (mean: 18.8%) and 13.9–27.0% (mean: 18.5%), respectively, indicating limited reproducibility in 3-HPMA analysis for both sample types. Re-calculation of the PU results by applying an embedded calibration (EC), derived from the reported peak areas for the LU test samples, somewhat improved the CVR values (range: 9.6–28.8%, mean: 16.7%).

It is concluded that the intra-laboratory variation (repeatability) in the determination of 3-HPMA in urine is in general acceptable in the participating laboratories, while the inter-laboratory variability requires further improvement. The relatively small reduction in the inter-laboratory variability (sR and CVR) by applying an EC suggests that other methodological factors than the standard reference material for 3-HPMA have to be addressed to achieve further improvement in reproducibility.

Language: English
Page range: 65 - 76
Submitted on: Jul 26, 2016
Accepted on: Nov 14, 2016
Published on: Feb 10, 2017
Published by: Institut für Tabakforschung GmbH
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2017 Gerhard Scherer, Wolf-Dieter Heller, Michael McEwan, Thomas Göen, Peter Joza, Nan Liu, Kirk Newland, Thomas Schettgen, Sheng Wang, Hyung-Ok Sohn, Valerie Troude, Dai Yuki, Saijing Zheng, Guojun Zhou, published by Institut für Tabakforschung GmbH
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.