Have a personal or library account? Click to login
Influence of RC Element Wiring in Electrical Circuit on Electromechanical Thermostat Contact Wear Cover

Influence of RC Element Wiring in Electrical Circuit on Electromechanical Thermostat Contact Wear

Open Access
|Sep 2016

Abstract

Contact wear caused by electric arc during electric contact make (cut-in) and break (cut-out) has the direct impact on the contact lifetime. The RC element wired parallelly to the contact will eliminate or reduce the arcing and subsequently extend the lifetime. Comparative tests of the two sets of identical Danfoss 077B electromechanical thermostats have been carried out. In the first batch, standard thermostats were tested. In the second batch, the same thermostat types, but with RC elements wired parallel to thermostats main contacts were tested. Measurement has not proven any improvement of the contact wear. Temperature drift and change of the critical dimension caused by contact wear were very similar in the both cases. Thus, the application of RC element is considered not reasonable measure for reduction of contact wear of electromechanical thermostats.

Language: English
Page range: 63 - 69
Published on: Sep 23, 2016
Published by: Slovak University of Agriculture in Nitra
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2016 Peter Haas, Milan Kadnár, Juraj Rusnák, František Tóth, Dušan Nógli, published by Slovak University of Agriculture in Nitra
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.