Abstract

Background: A number of studies reveal that home blood pressure variability is associated with cardiovascular risk factors. However, we do not have a consensus regarding the variability index and the frequency of measurements.

Objective: The aim of the study was to assess home blood pressure variability for a period of 7 consecutive days and 24-hour ambulatory blood pressure variability using the average real variability index and to test whether home blood pressure variability represents a suitable parameter for long-term monitoring of the hypertensive patients.

Material and methods: A number of 31 hypertensive patients were included in the study, 8 male, 23 female, mean age 60.19±7.35 years. At the inclusion ambulatory blood pressure monitoring was performed, home blood pressure monitoring was carried out for 7 consecutive days with 2 measurements daily. We compared ambulatory blood pressure values, variability using paired t-test. We were looking for correlations between HBP values and cardiovascular risk factors.

Results: Ambulatory versus home blood pressure derived mean blood pressure was 131.38±15.2 versus 131.93±8.25, p=0.81. Ambulatory derived variability was 10.65±2.05 versus home variability 10.56±4.83, p=0.91. Home versus ambulatory pulse pressure was 51.8± 9.06 mmHg vs. 54.9±11.9 mmHg, p=0.046. We found positive correlation between HBPV and home BP values, p=0.027, r2=0.1577, (CI: 0.04967 to 0.6588). Home, as well as ambulatory derived variability were positively correlated to age p=0.043, r2=0.1377 (CI: 0.01234 to 0.6451) versus p<0.0001, CI: 0.3870 to 0.8220, r2=0.4302.

Conclusion: Assessment of home blood pressure monitoring and variability could represent a well-tolerated alternative for long-term follow-up of hypertension management.

DOI: https://doi.org/10.1515/amma-2016-0020 | Journal eISSN: 2668-7763 | Journal ISSN: 2668-7755
Language: English
Page range: 239 - 242
Submitted on: Nov 29, 2015
|
Accepted on: Mar 20, 2016
|
Published on: May 20, 2016
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2016 Annamária Magdás, Boglárka Belényi, Adina Gaburoi, Alexandru Incze, published by University of Medicine, Pharmacy, Science and Technology of Targu Mures