Have a personal or library account? Click to login
Resin-Based Composite and LCU-related Factors Affecting the Degree of Cure. A Literature Review: Part 2. Light Curing Units & Related Factors Cover

Resin-Based Composite and LCU-related Factors Affecting the Degree of Cure. A Literature Review: Part 2. Light Curing Units & Related Factors

Open Access
|Jan 2016

References

  1. 1. Santini A. Current status of visible light activation units and the curing of light- activated resin-based composite materials. Dent Update. 2010;37,214-6,218-20,223-7.10.12968/denu.2010.37.4.214
  2. 2. Rueggeberg FA. State-of-the-art: dental photocuring-a review. Dent Mater. 2011;27,39-52.10.1016/j.dental.2010.10.021
  3. 3. Mills RW., Jandt KD., Ashworth SH. Dental composite depth of cure with halogen and blue light emitting diode technology. Br Dent J. 1999;186,388-91.
  4. 4. Pelissier B., Jacquot B., Palin WM., Shortall AC. Three generations of LED lights and clinical implications for optimizing their use. 1: from past to present. Dent Update. 2011;38,660-2,664-6,668-70.
  5. 5. Neumann MG., Schmitt CC., Ferreira GC., Correa IC. The initiating radical yields and the efficiency of polymerisation for various dental photoinitiators excited by different light curing units. Dent Mater. 2006;22,576-84.
  6. 6. da Silva EM., Poskus LT., Guimaraes JG., de Araujo Lima Barcellos A., Fellows CE. Influence of light polymerisation modes on degree of conversion and crosslink density of dental composites. J Mater Sci Mater Med. 2008;19,1027-32.
  7. 7. Rahiotis C., Patsouri K., Silikas N., Kakaboura A. Curing efficiency of high-intensity light-emitting diode (LED) devices. J Oral Sci. 2010.;52,187-95.
  8. 8. Rueggeberg F. Contemporary issues in photocuring. Compend Contin Educ Dent Suppl. 1999;S4-15.
  9. 9. Hofmann N., Hugo B., Klaiber B. Effect of irradiation type (LED or QTH) on photo- activated composite shrinkage strain kinetics, temperature rise, and hardness. Eur J Oral Sci. 2002;110,471-9.
  10. 10. Lindberg A., Peutzfeldt A., van Dijken JW. Curing depths of a universal hybrid and a flowable resin composite cured with quartz tungsten halogen and light-emitting diode units. Acta Odontol Scand. 2004;62,97-101.
  11. 11. Shortall AC. How light source and product shade influence cure depth for a contemporary composite. J Oral Rehabil. 2005;32,906-11.
  12. 12. Campregher UB., Samuel SM., Fortes CB., et al. Effectiveness of second-generation light-emitting diode (LED) light curing units. J Contemp Dent Pract. 2007;8,35-42.
  13. 13. Mills RW., Uhl A., Blackwell GB., Jandt KD. High power light emitting diode (LED) arrays versus halogen light polymerisation of oral biomaterials: Barcol hardness, compressive strength and radiometric properties. Biomaterials. 2002;23,2955-63.
  14. 14. Ikemura K., Ichizawa K., Yoshida M., Ito S.& Endo T. UV-VIS spectra and photoinitiation behaviors of acylphosphine oxide and bisacylphosphine oxide derivatives in unfilled, light-cured dental resins. Dent Mater J. 2008;27,765-74.
  15. 15. Arikawa H., Takahashi H., Kanie T. & Ban S. Effect of various visible light photoinitiators on the polymerisation and color of light-activated resins. Dent Mater J. 2009;28,454-60.
  16. 16. Ilie N., Hickel R. Can CQ be completely replaced by alternative initiators in dental adhesives? Dent Mater J. 2008;27,221-810.4012/dmj.27.221
  17. 17. Busemann I., Lipke C., Schattenberg A., Willershausen B., Ernst CP. Shortest exposure time possible with LED curing lights. Am J Dent. 2011;24,37-44.
  18. 18. Price RB., Fahey J., Felix CM. Knoop hardness of five composites cured with single-peak and polywave LED curing lights. Quintessence Int. 2010a;41,e181-91.
  19. 19. Sim JS., Seol HJ., Park JK., et al. Interaction of LED light with coinitiator-containing composite resins: effect of dual peaks. J Dent. 2012;40,836-42.
  20. 20. Alvim HH., Alecio AC., Vasconcellos WA., et al. Analysis of camphorquinone in composite resins as a function of shade. Dent Mater. 2007;23,1245-9.
  21. 21. Czasch P.& Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investi. 2013;17,227-35.10.1007/s00784-012-0702-8
  22. 22. Ferracane JL., Mitchem JC., Condon JR., Todd R. Wear and Marginal Breakdown of Composites with Various Degrees of Cure. Journal of Dental Research. 1997;76,1508-1516.
  23. 23. Park YJ., Chae KH.& Rawls HR. Development of a new photoinitiation system for dental light-cure composite resins. Dent Mater. 1999;15,120-7.
  24. 24. Moore BK., Platt JA., Borges G., Chu TM., Katsilieri I. Depth of cure of dental resin composites: ISO 4049 depth and micro-hardness of types of materials and shades. Oper Dent. 2008.;33,408-12.
  25. 25. Borges BC., Bezerra GV., Mesquita A., et al. Effect of irradiation times on the polymerisation depth of contemporary fissure sealants with different opacities. Braz Oral Res. 2011;25,135-42.
  26. 26. Davidson-Kaban SS., Davidson CL., Feilzer AJ., de Gee AJ., Erdilek N. The effect of curing light variations on bulk curing and wall-to-wall quality of two types and various shades of resin composites. Dent Mater. 1997;13,344-52.
  27. 27. Knezevic A., Tarle Z., Meniga A., et al. Degree of conversion and temperature rise during polymerisation of composite resin samples with blue diodes. J Oral Rehabil. 2001;28,586-91.
  28. 28. Santini A., Miletic V., Swift MD., Bradley M. Degree of conversion and microhardness of TPO-containing resin-based composites cured by polywave and monowave LED units. J Dent. 2012;40,577-84.
  29. 29. Ferracane JL. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins. Dent Mater. 1985;1,11-4.
  30. 30. Silikas N., Eliades G., Watts DC. Light intensity effects on resin- composite degree of conversion and shrinkage strain. Dent Mater. 2000;16,292-6.
  31. 31. Lohbauer U., Rahiotis C., Kramer N., Petschelt A., Eliades G. The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite. Dent Mater. 2005;21,608-15.
  32. 32. Shin DH.& Rawls HR. Degree of conversion and color stability of the light curing resin with new photoinitiator systems. Dent Mater. 2009;25,1030-8.
  33. 33. Peutzfeldt A. Resin composites in dentistry: the monomer systems. Eur J Oral Sci. 1997;105,97-116.10.1111/j.1600-0722.1997.tb00188.x
  34. 34. Calheiros FC., Daronch M., Rueggeberg FA., Braga RR. Degree of conversion and mechanical properties of a BisGMA: TEGDMA composite as a function of the applied radiant exposure. J Biomed Mater Res B Appl Biomater. 2008;84,503-9.
  35. 35. Floyd CJ., Dickens SH. Network structure of Bis-GMA- and UDMA-based resin systems. Dent Mater. 2006;22,1143-9.
  36. 36. Price RB., Mcleod ME., Felix CM. Quantifying light energy delivered to a Class I restoration. J Can Dent Assoc. 2010b;76,a23.
  37. 37. Peutzfeldt A., Asmussen E. Hardness of restorative resins: effect of camphorquinone, amine, and inhibitor. Acta Odontol Scand. 1989;47,229-31.
  38. 38. Kalliyana Krishnan V., Yamuna V. Effect of initiator concentration, exposure time and particle size of the filler upon the mechanical properties of a light-curing radiopaque dental composite. J Oral Rehabil. 1998;25,747-51.
  39. 39. Rueggeberg FA., Ergle JW., Lockwood PE. Effect ofphotoinitiator level on properties of a light-cured and post-cure heated model resin system. Dent Mater. 1997;13,360-4.
  40. 40. Yoshida K., Greener EH. Effect of photoinitiator on degree of conversion of unfilled light-cured resin. J Dent. 1994;22,296-9.
  41. 41. Leprince JG., Hadis M., Shortall AC., et al. Photoinitiator type and applicability of exposure reciprocity law in filled and unfilled photoactive resins. Dent Mater. 2011;27,157-64.
  42. 42. Miletic V., Santini A. Micro-Raman spectroscopic analysis of the degree of conversion of composite resins containing different initiators cured by polywave or monowave LED units. J Dent. 2012;40,106-13.
  43. 43. Neumann MG., Miranda WG. jr., Schmitt CC., Rueggeberg FA., Correa IC. Molar extinction coefficients and the photon absorption efficiency of dental photoinitiators and light curing units. J Dent. 2005;33,525-32.
  44. 44. Brandt WC., Schneider LF., Frollini E., Correr-Sobrinho L., Sinhoreti M. Effect of different photo-initiators and light curing units on degree of conversion of composites. Braz Oral Res. 2010;24,263-70.
  45. 45. Palin WM., Senyilmaz DP., Marquis PM., Shortall AC. Cure width potential for MOD resin composite molar restorations. Dent Mate. 2008;24,1083-94.
  46. 46. Myers ML., Caughman WF.& Rueggeberg FA. Effect of restoration composition, shade, and thickness on the cure of a photoactivated resin cement. J Prosthodont. 1994;3,149-57.
  47. 47. Lazarchik DA., Hammond BD., Sikes CL., Looney SW., Rueggeberg FA. Hardness comparison of bulk-filled/transtooth and incremental-filled/occlusally irradiated composite resins. The Journal of Prosthetic Dentistry. 2007;98,129-140.
  48. 48. Ogunyinka A., Palin WM., Shortall AC., Marquis PM. Photoinitiation chemistry affects light transmission and degree of conversion of curing experimental dental resin composites. Dent Mater. 2007;23,807-13.
  49. 49. Price RB., Murphy DG., Derand T. Light energy transmission through cured resin composite and human dentin. Quintessence Int. 2000;31,659-67.
  50. 50. Arcis RW., Lopez-Macipe A., Toledano M., et al. Mechanical properties of visible light-cured resins reinforced with hydroxyapatite for dental restoration. Dent Mater. 2002;18,49-57.
  51. 51. Thome T., Steagall W. Jr., Tachibana A., Braga SR., Turbino ML. Influence of the distance of the curing light source and composite shade on hardness of two composites. J Appl Oral Sci. 2007;15,486-91.
  52. 52. Shortall AC., Palin WM., Burtscher P. Refractive index mismatch and monomer reactivity influence composite curing depth. J Dent Res. 2008;87,84-8.
  53. 53. Caughman WF., Rueggeberg FA.& Curtis JW. Jr. Clinical guidelines for photocuring restorative resins. J Am Dent Assoc. 1995;126,1280-2,1284,1286.
  54. 54. Guiraldo RD., Consani S., Consani RL., et al. Light energy transmission through composite influenced by material shades. Bull Tokyo Dent Coll. 2009;50,183-90.
  55. 55. Alshali RZ., Silikas N.& Satterthwaite JD. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mater. 2013;29,e213-710.1016/j.dental.2013.05.011
  56. 56. Jeong TS., Kang HS., Kim SK., et al. The effect of resin shades on microhardness, polymerisation shrinkage, and color change of dental composite resins. Dent Mater J. 2009;28,438-45.
  57. 57. Rueggeberg FA., Caughman WF., Curtis JW. Jr.& Davis HC. Factors affecting cure at depths within light-activated resin composites. Am J Dent. 1993;6,91-5.
  58. 58. Pilo R., Oelgiesser D.& Cardash HS. A survey of output intensity and potential for depth of cure among light-curing units in clinical use. J Dent. 1999;27,235-41.
  59. 59. Yap AU. Effectiveness of polymerisation in composite restoratives claiming bulk placement: impact of cavity depth and exposure time. Oper Dent. 2000;25,113-20.
  60. 60. Harrington E.& Wilson HJ. Depth of cure of radiation-activated materials-effect of mould material and cavity size. J Dent. 1993;21,305-11.10.1016/0300-5712(93)90114-6
  61. 61. Hadis MA., Shortall AC.& Palin WM. Specimen aspect ratio and light transmission in photoactive dental resins. Dent Mater. 2012;28,1154-61.
  62. 62. Stansbury JW. Curing dental resins and composites by photopolymerisation. J Esthet Dent, 2000;12,300-8.10.1111/j.1708-8240.2000.tb00239.x14743525
  63. 63. Unn WJ.& Bush AC. A comparison of polymerisation by light- emitting diode and halogen-based light-curing units. J Am Dent Assoc. 2002;133,335-41.10.14219/jada.archive.2002.017311934189
  64. 64. Price RB.& Felix CA. Effect of delivering light in specific narrow bandwidths from 394 to 515nm on the micro-hardness of resin composites. Dent Mater. 2009;25,899-908.10.1016/j.dental.2009.01.09819243817
  65. 65. Rueggeberg FA., Caughman WF.& Curtis JW. Jr. Effect of light intensity and exposure duration on cure of resin composite. Oper Dent. 1994a;19,26-32.
  66. 66. Peutzfeldt A.& Asmussen E. Resin Composite Properties and Energy Density of Light Cure. Journal of Dental Research. 2005;84,659-662.10.1177/15440591050840071515972597
  67. 67. Abate PF., Zahra VN.& Macchi RL. Effect of photopolymerisation variables on composite hardness. J Prosthet Dent. 2001;86,632-5.
  68. 68. Lindberg A., Peutzfeldt A.& van Dijken JW. Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure. Clin Oral Investig. 2005;9,71-6.
  69. 69. Leloup G., Holvoet PE., Bebelman S.& Devaux J. Raman scattering determination of the depth of cure of light-activated composites: influence of different clinically relevant parameters. J Oral Rehabil. 2002;29,510-5.
  70. 70. Ceballos L., Fuentes MV., Tafalla H., et al. Curing effectiveness of resin composites at different exposure times using LED and halogen units. Med Oral Patol Oral Cir Bucal. 2009;14,E51-6.
  71. 71. Zhu S.& Platt J. Curing efficiency of three different curing modes at different distances for four composites. Oper Dent. 2011;36,362-71.10.2341/09-245-L21834705
  72. 72. Leprince JG., Lamblin G., Devaux J., et al. Irradiation modes’ impact on radical entrapment in photoactive resins. J Dent Res. 2010;89,1494-8.
  73. 73. Emami N.& Soderholm KJ. How light irradiance and curing time affect monomer conversion in light-cured resin composites. Eur J Oral Sci. 2003;111,536-42.10.1111/j.0909-8836.2003.00082.x14632692
  74. 74. Halvorson RH., Erickson RL.& Davidson CL. Energy dependent polymerisation of resin-based composite. Dent Mater. 2002/18,463-9.
  75. 75. Nitta K. Effect of light guide tip diameter of LED-light curing unit on polymerisation of light-cured composites. Dent Mater. 2005/21,217-23.10.1016/j.dental.2004.03.00815705428
  76. 76. Rode KM., Kawano Y.& Turbino ML. Evaluation of curing light distance on resin composite microhardness and polymerisation. Oper Dent. 2007;32,571-8.
  77. 77. Pires JA., Cvitko E., Denehy GE.& Swift EJ. Jr. Effects of curing tip distance on light intensity and composite resin microhardness. Quintessence Int. 1993;24,517-21.
  78. 78. RUEGGEBERG F. A. & JORDAN D. M. Effect of light-tip distance on polymerisation of resin composite. Int J Prosthodont. 1993;6,364-70.
  79. 79. Pianelli C., Devaux J., Bebelman S.& Leloup G. The micro-Raman spectroscopy, a useful tool to determine the degree of conversion of light-activated composite resins. J Biomed Mater Res. 1999;48,675-81.
  80. 80. de Santis A., Baldi M. Photo-polymerisation of composite resins measured by micro-Raman spectroscopy. Polymer. 2004;45,3797-3804.
  81. 81. Rueggeberg FA., Craig RG. Correlation of parameters used to estimate monomer conversion in a light-cured composite. J Dent Res. 1988;67,932-7.
  82. 82. Bouschlicher MR., Rueggeberg FA., Wilson BM. Correlation of bottom-to-top surface microhardness and conversion ratios for a variety of resin composite compositions. Oper Dent. 2004;29,698-704.
  83. 83. Shortall AC., Harrington E., Wilson HJ. Light curing unit effectiveness assessed by dental radiometers. J Dent. 1995a.;23,227-32.
  84. 84. Aguiar FH., Braceiro A., Lima DA., Ambrosano GM., Lovadino JR. Effect of light curing modes and light curing time on the microhardness of a hybrid composite resin. J Contemp Dent Pract. 2007;8,1-8.
  85. 85. Leonard DL., Charlton DG., Hilton TJ. Effect of curing-tip diameter on the accuracy of dental radiometers. Oper Dent 1999;24,31-7.
  86. 86. Roberts HW., Vandewalle KS., Berzins DW.& Charlton DG. Accuracy of LED and halogen radiometers using different light sources. J Esthet Restor Dent. 2006;18,214-22;discussion223-4.
  87. 87. Hansen EK.& Asmussen E. Reliability of three dental radiometers. Scand J Dent Res. 1993;101,115-9.10.1111/j.1600-0722.1993.tb01099.x8456251
DOI: https://doi.org/10.1515/amma-2015-0127 | Journal eISSN: 2668-7763 | Journal ISSN: 2668-7755
Language: English
Page range: 255 - 260
Submitted on: Aug 8, 2015
Accepted on: Sep 15, 2015
Published on: Jan 19, 2016
Published by: University of Medicine, Pharmacy, Science and Technology of Targu Mures
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2016 Aldossary Mohammed, Santini Ario, published by University of Medicine, Pharmacy, Science and Technology of Targu Mures
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.