Have a personal or library account? Click to login
Serum and Urine Copper – Contamination and Stability Cover

Serum and Urine Copper – Contamination and Stability

Open Access
|Nov 2015

References

  1. 1. Anand, V., White, J., Hippolto, N. Some aspects of specimen collection and stability in trace element analysis of body fluids.- Clin. Chem, 1975, 21/4, 595-602.10.1093/clinchem/21.4.595
  2. 2. Bonini, P., Plebani, M., Cerrioti, F., Rubboli, Fr. Errors in laboratory medicine.- Clin Chem, 2002, 48(5), 691-8.10.1093/clinchem/48.5.691
  3. 3. Bornhorst, J., Hunt, J., Urry, F., McMillin, G. Comparison of Sample Preservation Methods for Clinical Trace Element Analysis by Inductively Coupled PlasmaMass Spectrometry.- Am J Clin Pathol, 2005, 123, 578-583.10.1309/L241WUER8831GLWB
  4. 4. Bowen, R., Remaley, A. Interferences from blood collection tube components on clinical chemistry assay.- Biochem Med, 2014, 24(1), 31-44.10.11613/BM.2014.006393698524627713
  5. 5. Control of Pre-analytical Variation in Trace Element Determinations, Approved Guideline, NCCLS document C38-A (ISBN 1-56238-332-9). NCCLS, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087 USA, 1997.
  6. 6. IUPAC, Pure and Applied Chemistry 67, 1995, 1575-1608.10.1351/pac199567081575
  7. 7. Ivanova, I., Krastev, Z., Petkova, T., Dragneva, S. Comparison between 6-hour and 24-hour cupriuria in monitoring of therapy with D-penicillamine in patients with Wilson disease.- Biochem Med, 2013, 23(1), A1-A55.
  8. 8. Lauwerys, R., Amery, A., Bernard, A. et al. Health effects of environmental exposure to cadmium: objectives, design and organization of the Cadmibel Study: a cross-sectional morbidity study carried out in Belgium from 1985 to 1989.- Environ Health Perspect, 1990, 87, 283-9.10.1289/ehp.908728315678392269233
  9. 9. Lippi, G., Banfi , G., Church, S. et al. Preanalytical quality improvement. In pursuit of harmony, on behalf of European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working group for Preanalytical Phase (WG-PRE).- Clin Chem Lab Med, 2014, 1-14.10.1515/cclm-2014-105125490032
  10. 10. Oddoze, C., Lombard, E., Portugal, H. Stability studies of 81 analytes in human whole blood, in serum and plasma.- Clin Biochem, 2012; 45: 464-9.10.1016/j.clinbiochem.2012.01.01222285385
  11. 11. Plebani, M. Errors in clinical laboratory or errors in laboratory medicine? Clin Chem Lab Med. 2006; 44(6):750-59.10.1515/CCLM.2006.12316729864
  12. 12. Plebani, M., Sciacovelli, L., Aita, A., Chiozza, M.L. Harmonization of pre-analytical quality indicators. - Biochem Med, 2014; 24(1):105-13.10.11613/BM.2014.012393697024627719
  13. 13. Trace elements in human and animal nutrition, fi fth edition. Beltsville Meryland, Walter Mertz, Academic press, 1987, Volume 1.
  14. 14. Welz, B. Atomic Absorption Spectroscopy. Verlag Chemie. Weinheim, New York, 1976.
  15. 15. Westgard QC. Desirable specifi cations for total error, imprecision and bias, derived from intra- and inter-individual biological variation. Available at: www.westgard.com/biodatabase1.htm#11, 2012.
DOI: https://doi.org/10.1515/amb-2015-0018 | Journal eISSN: 2719-5384 | Journal ISSN: 0324-1750
Language: English
Page range: 49 - 60
Published on: Nov 26, 2015
Published by: Sofia Medical University
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2015 I. Dimitrova Ivanova, B. Atanasova, S. Dragneva, L. Vladimirova, Z. Krastev, A. Kostadinova, A. Ivanova, K. Tzatchev, published by Sofia Medical University
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.